2-10 Installation MN1240
Strain Relief (Mounted at Terminal Box)
The motor cable is terminated at the Terminal Box using a Shielded Strain Relief
Connector. Figure 2-8 shows the components.
1. Strip the outer shield from the cable to expose the conductors and
shield.
2. Slip the Strain Relief components onto the cable in the order shown.
3. Fold the Shield wires over the end of the Contact Carrier.
4. Slide the Threaded Adapter onto the Contact Carrier until the Carrier is
completely inserted into the Adapter.
5. Slide the Gasket into the Contact Carrier.
6. Slide the Adapter Cover onto the Threaded Adapter and Tighten. As it is
tightened, it compresses the Gasket against the Cable to form the strain
relief and securely hold the cable.
7. The assembly can be inserted into the Terminal Box and secured.
Figure 2-8 Motor Cable Strain Relief Assembly
Threaded
Adapter
Gasket Adapter
Cover
Contact
Carrier
Shielded Cable
Assemble Parts onto Cable
Assembled
Fold Shield wires over Contact Carrier