Seitenansicht 16
MN1240 Installation 2-9
Electrical Connections
Overview Figure 2-6 shows typical connections to a control. Note all wiring
should be 600volts.
Figure 2-6 Typical Connections to Motor Control
AC MotorU
VW
G
Control
Feedback
Motor
Holding
Brake
Motor
Temperature
Switch
Shielded
Twisted Pair Wire
Shielded
Twisted Pair Wire
Feedback
Connector
Motor
Connector
Motor Ground Wire
Motor Temperature Input
Holding Brake Connector
Single Point Ground
Shielded Motor Cable
All wiring should have 600V rated insulation.
Motor Lead Termination
Motor leads are normally terminated using a Connector or Terminal Box (see
Figure 2-7) or Flying Leads. When no termination is provided and the motor
leads just exit the motor housing, this is called “Flying Leads”. For flying
leads, refer to the motor packing list to determine the lead configuration.
Figure 2-7 Motor Termination
Terminal Box Termination
8 Pin
Function Pin
Thermal Switch A
Thermal Switch B
Brake C
Brake D
U1
Ground 2
W3
V4
Connector Termination
1
D
2
3
4
C
B
A
Function Pin
Thermal Switch 1
Thermal Switch 2
Brake 3
Brake 4
UU
VV
WW
Ground (P.E.) Screw