AN00174-001 Modbus TCP Fieldbus Option for MotiFlex e100.doc
7
77
7 of
of of
of 22
2222
22
There are two icons for mapped Process Data:
• Receive – data sent from the PLC to the drive
• Transmit – data sent from the drive to the PLC
Click on the dropdown to see the full list of pre-defined
objects (the Custom object can be used to access a
wider range of drive objects – see the Mint Help File for
full details of the drive’s object dictionary).
For the purposes of this Application Note we are going
to map two NetData Process Data Objects from the PLC
to the drive.
Later on we will map these two NetData values to our
NextMove e100 so effectively the PLC is able to write
two data values to the NextMove using the drive as a
Gateway.
Select NetData from the list.
Double click the Receive icon (or single
click and then click on the yellow +
button). WorkBench now displays a dialog
allowing the user to select where the first
PDO data received from the PLC should be
mapped to on the drive: