WorkBench shows us which EPL devices have already been added to the NextMove’s DCF (in our
case none as we have started a new configuration). Click on ‘Add Device…’ to add a new EPL node
(click on ‘Edit Device…’ if you already have the MotiFlex e100 with Fieldbus Option included in the
DCF).
Select MotiFlex e100 as the device type
and select the appropriate Ethernet
Powerlink Node ID.
As described earlier we set our EPL rotary
switches to 02 to select EPL Node ID 2.
The dialog shows the available resources
on the MotiFlex e100 that can be mapped
back to the NextMove e100.
Click on ‘OK’.
WorkBench v5.5 now displays a dialog
that shows which resources have been
mapped from the drive to the NextMove
e100. Initially (as we’ve only just added
this drive as a new device) there are red
crosses against everything to show
nothing is mapped).
The dialog also shows how many of the
possible 64 PDO items to and from the
MotiFlex have been mapped. Note that
mapping an Axis and drive resources will
consume some of these PDOs thereby
restricting the amount of data that can be
passed to/from the FOC.
For the purposes of this Application Note
we don’t need to map an Axis, Digital I/O
or an Encoder but as it’s most common to
actually be using the drive as a controlled
axis (rather than just as a Gateway) we
will illustrate this just for reference.
Double-click the ‘Axis 0’ icon to display
the Axis 0 mapping dialog.