Receiving & Installation 3-5
MN2417
Single Phase Connections
Single phase connections are made at load receptacles located by the operator panel, see
Figure 3-3. Simply open the rear panel access door and make the connections. When the panel
door is closed, the connections are weather tight.
Figure 3-3 Receptacle Panel (Single Phase)
Single phase power is
always available.
(GOLD)
X
(GOLD)
Y
G
(SILVER)
W
CS6369
125/250V
50A
X
Y
W
Test
Reset
CS6365N
GFI Outlet
120V, 20A
STD Outlet
120V, 20A
240V, 50A
Circuit Breakers (Single or Double pole)
Circuit Breakers provides protection on some
units. To reset a breaker, place it in the OFF
then the ON position.
Single pole breaker
for 120VAC outlets
Double pole breaker
for 240VAC outlets